Shanghai Yi Hua V&A Instrument Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Cheng Mary
  • Company Name : Shanghai Yi Hua V&A Instrument Co., Ltd.
  • Tel : 86-021-69521064
  • Fax : 86-021-69523221
  • Address : Shanghai,Jiading District,881 Yecheng Rd,
  • Country/Region : China
  • Zip : 201821

VA82 5 1/2 Digital bench multimeter

VA82 5 1/2 Digital bench multimeter
Product Detailed
Related Categories:Multimeters
VA82 5 1/2 Digital bench multimeter

Key Features:

2 different measurement functions: DCV/ACV, DCI/ACI, Ω2W/Ω4W, frequency/period, diode test, continuity, dB/dBm, etc.

High-brightness vacuum fluorescent display (VFD)

True-rms AC voltage and current measurement, with high frequency of 100kHz

Maximum reading of 120,000 digits

DCV measurement accuracy up to 0.01%, resolution 1µV

Maximum measurement rate: 45times/second

Equal accuracy frequency measurement more than 1MHz, minimum resolution of 10μHz

Zeroing (RFL) mode to eliminate residual reading

2W and 4W resistance measurement modes selectable

Built-in mathematics calculation functions: mX+b, %, dB, dBm

512 readings storage and MAX/MIN/AVER/STD statistics

HI/IN/LO comparator function

GPIB and RS-232 interfaces for convenient system communication,

Calibration performed without opening the cover

10 sets of measurement states saved and recalled up                      

Measurement function

Measurement parameters

DC voltage, AC voltage, DC current, AC current,2-wire resistance, 4-wire resistance, frequency, period, continuity, diode

Mathematic function

mX+b, %, dB, dBm, REL

Range

Auto, manual

Display

VFD

Trigger mode

INT/MAN/BUS

Programmable delay

0~6000mS

Reading storage & statistics

2 to 512 readings can be stored, loaded and counted

Type of  statistics: MAX,MIN,AVER,STD

Reading hold

To find out best stable reading for each data block of the given reading number according to the given accuracy.

Limit measurement

To judge HI,IN,LO and display, with ALARM for HI/LO

Storage setup

10 setting files can be stored and loaded

Calibration

Recommended Fluke5520A with TH1951/TH1961 Accurate Calibration software ( option )

Communication interface

GPIB (option), RS232C, SCPI command programming support

Function parameter

Measurement condition

Calibration cycle: one year

Operating temperature & humidity:18°C-28°C,≤90%RH;

When resistance range is 10M and 100M, ≤70%RH

Warm-up time:30 minutes

Accuracy expressed as:± (% of reading + % of range)

Temperature coefficient: 0°C--18°C 28°C--40°C,+0.1×accuracy /°C

The following specifications are at slow mode, and please refer to the operation manual for other details.

VA82 5 1/2 Digital bench multimeter



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.